|
ATR Infos Safenet Model 330
| ATR Infos e-card
|
ATR Infos Telesec TCOS 2.0 |
| |
|
|
|
The standard ATR of the Telesec TCOS 2. 0 based on the SLE 66CX 320P Chip of Infineon is: 3b ba 14 00 81 31 86 5d 00 64 05 14 02 02 31 80 90 00 91 (picture is showing a TCOS netkey Card)
|
 |
 |
 |
TCOSmin V2.0. |
|
|
|
TS=0x3b (direct) |
f(min)=1000kHz (default) |
|
T0=0xba (Y(1)=11,K=10) |
f(max)=5000kHz |
|
TA(1)=0x14 (FI=1,DI=4) |
Fi=372 |
|
TB(1)=0x00 (II=0,PI1=0) |
Di=8 |
|
TD(1)=0x81 (Y(2)=8,T=1) |
N=0 (default) |
|
TD(2)=0x31 (Y(3)=3,T=1) |
P=0dV |
|
TA(3)=0x86 (IFSC=134) |
I=25mA |
|
TB(3)=0x5d (BWI=5,CWI=13) |
X=Not supported (default) |
|
T1=0x00 |
U=A only (default) |
|
T2=0x64 'd' |
IFSC=134 |
|
T3=0x05 |
BWI=5 |
|
T4=0x14 |
CWI=13 |
|
T5=0x02 |
EDC=LRC (default) |
|
T6=0x02 |
T(supp)=1 |
|
T7=0x31 '1' |
|
|
T8=0x80 |
|
|
T9=0x90 |
|
|
T10=0x00 |
|
|
TCK=0x91 |
|
|
 |
 |
 |
 |
 |
|
Meaning of the Parameter |
As seen above, the single bytes of the ATR indicate certain values.
f(min): minimum frequency for communication with the card f(max): maximum frequency, for communication with the card Fi: Clock rate conversion factor. Di: Baude rate adjustment factor. N: Extra guardtime P: programming voltage I: programming power X: Clock stop indicator U: Class indicator for operating condition. class A = 5V, class B = 3V IFSC: Maximum information field size for cards; maximum length of blocks, the card can receive BWI: Block waiting time integer. The maximum delay between rising (front) edge of the last character in a block to the rising (front) edge of the next block. CWI: Character waiting time integer. The maximum delay between the rising (front) edges of to consecutive characters within a block.EDC: Error detection code. Gibt die Art der Error Detection (LRC, CRC) an.T: Protokoll Typ.
|
Conclusion |
The performance results of a card reader depends strongly on the used smart card. To compute the etu (elementary time unit), the time length for transmittance of one bit, you need the frequency and the conversion and the adjustment factor. The formula is
1 etu = (F/D) * (1/f)
F = Clock rate conversion factor D= Baud rate adjustment factor f = Frequency (Hz)
Concretely the TCOS 2.0 card results in an etu about ap. 9ms (Fi = 372, Di = 8, f = 5 MHz). For the user more interesting is the baudrate of the communication with the card. You can compute it with:
Baudrate = (f/F) * D
The TCOS 2.0 has a maximum baudrate of 107526. This value is accepted by the card. Crucial is the frequency of the card reader - resulting in other baudrates. Due to this facts it is possible, that a card reader can communicate very fast with one card, while another card seems to be extremely slow. You can see this perception in your Reader Test.
|
|
|
|
|
|
|
|
|
|
|